Roof tile ventilation

Tudor offers three kinds of roof tile ventilation that don’t spoil a handmade roof: the patented Under-Tile vent, which can’t be seen (about 9,000 mm² of free air), the low-profile In-Tile vent (at least 6,000 mm²) and vented ridge tiles (2,580 mm² each).

Request samplesCall 01797 320202

Tudor In-Tile roof vent
Tudor Under-Tile vent being fitted under handmade tiles

Under-Tile vent: invisible

Our patented Under-Tile vent sits beneath the tiles and uses the deep cross camber of Tudor tiles. Each tile leaves a gap of about 6 mm tapering to nothing, giving around 480 mm² of airflow per tile and about 9,000 mm² across the 12 tiles over one vent.

It suits soil and mechanical vent pipes where an external pressure test isn’t required, works with warm roof construction, and fits new builds and renovations. It was developed with the co-operation of county planning and building control.

Flatter tiles from other makers may reduce its performance.

Tudor In-Tile vent on a clay tile roof

In-Tile vent: semi-visible

The In-Tile vent is a low-profile vent made exclusively for Tudor by Hambleside Danelaw of Northampton. Each one gives at least 6,000 mm² of free vent area and suits soil and mechanical vent pipes.

On site, the roofer covers it with tiles from your own batch using a good building adhesive, so it is barely visible. It works with any brand of clay plain tile and can be fitted to an existing roof.

Comparing the three

Under-Tile ventIn-Tile ventVented ridge
How it looksInvisibleSemi-visible, covered with tilesA slot in the ridge
Free vent areaAbout 9,000 mm² (14 in²)At least 6,000 mm² (9.3 in²)2,580 mm² (4 in²) per ridge
Soil pipes and fansYesYesNo: natural airflow only
Other tile brandsBest with Tudor tilesAny clay plain tileTudor ridges
SizeSkirt 1980 × 455 mm, mouth 265 × 42 mm310 × 330 mmAbout 310 mm long

The Under-Tile and In-Tile systems each come in three parts: the vent, a flexi-pipe and a vent-to-pipe adapter. Each part is sold separately.

Roof tile ventilation and building regulations

Well-insulated modern roofs trap moisture, so ventilation matters. BS 5534, the code of practice for slating and tiling, recommends roof ventilation in line with BS 5250, the code for controlling condensation, which uses ISO 13788 to calculate the risk.

For roof space, mechanical and soil pipe venting, the Under-Tile system is deemed to comply with the relevant building regulations. Your designer or building control officer will confirm what a particular roof needs; the government publishes the approved documents online.

Questions about roof ventilation

Can I use the Under-Tile vent with other tiles?

It is designed around the deep camber of Tudor tiles. Flatter tiles from other makers may reduce how much air it moves.

Can an In-Tile vent be fitted to an existing roof?

Yes. It can be fitted retrospectively and works with any brand of clay plain tile.

Can a vented ridge take a soil pipe or extractor fan?

No. Vented ridges give natural ventilation along the ridge only. Use an Under-Tile or In-Tile vent for pipes and fans.

What comes with a vent?

Each system has three parts, the vent, a flexi-pipe and a vent-to-pipe adapter, all sold separately.

See the tiles before you choose

We deliver samples by hand wherever we can, and you are welcome at the factory in Lydd by appointment.

Request samplesArrange a factory visit

Talk to the team

01797 320202

Dengemarsh Road, Lydd, Kent TN29 9JH